| The company provides
series of spare parts and installation service in spots or
spots installation guide at customer¡¯s inquiry with quick
speed to reduce customer¡¯s cost.
Terrace installation:
There is at least left 4mm for grating bearing steel and 6mm
space between Gratings, and 10mm space between the Gratings
and cement.
Use M type or L type clip to fix between the Grating and bearing
steel; at lease 4 clips for each Grating; Use C type clip
between non-bearing Gratings and at least 1 clip for each
1.8m length Grating
Trench installation:
The trench size should be times, if possible, of the lattice
size to keep the completeness of the lattice and the beauty
of the trench;
There should be at least 40mm space cement ground for bearing
the Grating and 3mm ¨C 6mm space between the Grating and cement.
Stair tread installation:
The stair tread should be installed in the tread frame. The
tread frame could be either steel or FRP ones.
There should be 3mm ¨C 6mm space between the tread and the
frame. Each tread needs 8 clips to fix and 2 clips for each
angle.
There are three types of clips: M type, L type and C type,
which has different usage. The M type clip will be used between
grating and bearing steel to locate the grating. The L type
clip will be used between grating and bearing steel to limitedly
locate the grating. The C type clip will be used between grating
side and grating side. The clip spare parts (such as bolt,
gasket, etc.) are also available.
Maintenance:
No need maintaining except washing surface dust and
dirt with washing detergent.
Avoiding any open fire caused by electric and oxygen welding
when repairing or maintaining the bearing steel and equipment.
Avoiding be contaminating by oil and knocking by sharp and
solid tools when repairing or maintaining the bearing steel
and equipment.
|