In order to prevent FRP tanks
from slipping, colliding during transportation, they should be fixed
tightly after loading and then put soft interleaver into the gap
between tank and carriage.
The tank should be lift by stationary rings or strong cloth strip,
when suspending installed, a rope should be tied to the tank, which
could control the direction of tank, avoiding swing.
The tank should not roll on the rigid ground, components such as
flange should not be extruded and collided.
Vertical tank with flat bottom should be installed on the basis
of continuous support and enough strength as well, less or lighter
FRP equipment must be fixed on the basis, avoiding the equipment
capsize.
Valve, controller, blender and other heavy components, which are
installed on the tank, additional support must be set them, avoiding
to transfer load to the wall tank.
The tank is used to store medium stipulated in technique document
under stipulated temperature, pressure. And the load is no more
than the design volume.
when enter into the tank to clean or maintain, the metal component
should not touch the tank directly, the touch point must be with
cork or glue.
During usage, the tank is forbidden to contact the light.
During usage, the tank should be avoided quivering. Pass in and
out flange connection should be joint gently, in order to minish
quivering, avert wring.
Adding shank should not be used when install manhole, flange and
other snail connected to FRP, stop when hear the noise.
Contact the manufacture immediately when the singularity happen
during installation or usage.
|